Key Product Features
- Simple 2-button operation
- Automatic hydrocarbon range selection
- Gas/Air and Gas/Nitrogen/ Air purge mode
- Can be calibrated via an IR link to GMI auto test
The Oxygas 500 compliments the Gascoseeker 500 with a similar performance, measuring % LEL and % volume flammable hydrocarbons, but with the addition of oxygen for either gas/air or gas/nitrogen/air purging. The Oxygas 500 has the following additional features; automated zero during start-up, manually selectable purge mode.
The P-500 variant has an additional part per million (ppm) range of methane.
The Oxygas 500 is easy to use with very simple training, as the operation of the instrument follows the operation of the purge cycle. The rugged design allows the Oxygas 500 to be used in harsh environments. The instrument is also fully compatible with our range of calibration software and equipment.
- Automatic hydrocarbon range selection
- ppm range manually selected on P-500 variant
- Manual selection of purge mode
- Simple 2-button operation, allowing user access to all features
- Automatic zero
- Gas/air and gas/nitrogen/air purge mode
- Hydrocarbon resolution to equivalent of 50 ppm methane
- Accurate, robust and extremely reliable
- Integral pump with flow-path protected by water filter
- Rugged carbon loaded polypropylene case, sealed to IP54 rating and suitable for outdoor use
- LCD with backlighting which displays the current gas readings (in both digital and analogue format), together with operational and status information
- Can be checked/calibrated, via an infra-red link to GMI Auto Test Calibration Unit, without opening the instrument
- Comprehensive range of accessories
- ATEX approved
|
Measuring Ranges
|
Resolution
|
|
0 - 25% Oxygen (O2)
0 - 100% Vol Gas
0 - 100% LEL
0 - 1000 ppm Flammable (Oxygas P-500 only)
|
Oxygen 0 - 21%
Oxygen 21 - 25%
Vol Gas 0 - 100%
LEL 0 - 10%
LEL 10 - 100%
ppm Flam. 0 - 1000
|
0.1%
1%
1%
0.1%
1%
5ppm
|
|
Certification
|
Environment
|
|
ATEX
UL
CSA
IECEx
MED 
Download Product Datasheet for Details
|
Temperature Limits:
- 20 Deg.C to + 50 Deg.C (- 4 Deg.F to + 122 Deg.F)
Humidity:
0 - 95% RH non-condensing
|
|
Power Supply
|
Sampling System
|
|
4 ‘D’ size alkaline cells providing approx. 15 hours'
runtime at 20 Deg.C (68 Deg.F)
Rechargeable (NiCd) battery pack providing approx.
9 hours' runtime at 20 Deg.C (68 Deg.F).
Geiger (Ticker)
Indicates gas concentration increase in ppm range
via the increased rate of sounder and LED pulse
(Oxygas P-500 only)
|
Integral pump with flow fail sensor
Sample path protected by hydrophobic filter and auto pump switch off
|
|
Physical Properties
|
|
Dimensions:
180 (H) x 95 (W) x 105 (D) mm
7.1 (H) x 3.7 (W) x 4.1 (D) in.
Weight:
1.2kg (2.5 lbs) with alkaline batteries
|
Moulded polypropylene case protected to IP54
Display:
LCD containing:
4-digit digital display
Analogue display
3-character range indication
Operational flags
|
- Leak detection
- Bar hole survey
- Gas/air or gas/nitrogen/air purging
- Gas escape detection
- Hot work permitting
- Leak source detection (ppm variant)
|