Seafarer
Key Product Features
- Cost effective Multi-channel sampling system
- Suitable where detector placement is a problem
- Approved for marine use
- Multi-lingual capability
The Seafarer product from GMI is the culmination of several generations of GMI sampling systems, it has been designed to monitor gas levels on board ships and many other applications. This system pumps potentially hazardous gas from a number of sample points, sighted where the positioning of conventional gas sensors may not be practical. This may be due to equipment security, cable routing, access for detector head installation / maintenance in harsh environments.
Gas samples are sequentially extracted for a variable time period by a central control unit via up to 48 fixed sample lines. A high rate of sample is pulled by the main pump and then a reduced rate sample is passed across the sensor device to enable a fast response to hazardous conditions. The central unit provides gas level readouts with two alarm trip points per line, providing a range of signal outputs to the annunciator and for control functions. The system also can provide for remote displays where several different locations need to be aware of the system status.
GMI have used our many years of sample system experience to ensure that this system combines high reliability with ease of use and installation.
- 1 – 48 Sample points
- Monitor up to 4 gas types
- Full indication of all operations
- 4 Line alpha / numeric display
- Line blockage and pump fail monitoring
- Variable sample time for optimum cycle time
- Selectable sample line sequence
- No sample line purge delay
- High integrity, comprehensive self check fault monitoring
|
Specification
|
Outputs
|
|
Sample Points 1 – 48
Sensors 1 – 4 4~20mA input
Measurements Combustible Gas: LEL ; % Vol. Toxic Gas: PPM ; % Vol. Oxygen: % Vol. Depletion / Enrichment Refrigerant - ppm
Response time: 15 to 45 seconds
User Interface 8 Panel mounted push buttons: Reset ; Scroll ; Hold ; Dim ; Enter ; Down ; Up ; Select.
General LED / display dimming User / Eng password LCD backlight Event logging
|
PC - Event log / Data log, data to and from system controls. Relay Outputs Global Low S.P.C.O. Global High S.P.C.O. Flow Fail S.P.C.O. Power Fail S.P.C.O. Cabinet Sensor S.P.C.O. 32 programmable relays + 32 optional All contacts rated at 5A – 230v AC Communication RS232 – Data Stream Modbus: 2 x RS485 Can bus – internal
|
|
Display
|
Alarms
|
|
4 Line alpha / numeric indicates all functions and status in text. Sample line locations - User settable LED Indicators System Healthy,Main Power, Standby Power High Gas Alarm, Low Gas Alarm, System Fail,Flow Fail, Sensor Fail, Comms. Fail,Skip / Hold, Sampling
|
Audible alarm all alarm conditions
|
|
Power Supply
|
Environmental
|
|
230/115v AC 50/60 Hz
|
IP 63 rated enclusure
|
|
Physical Properties
|
|
Dimensions: 800mm.(H) x 600mm.(W) x 360mm.(D)
19in. Rack based option
Cabinet Colour - Ash Grey (BS A01)
Weight: 56Kg.
|
Sample line size 8mm. O/D ; 6mm. I/D Nylon ; PTFE ; Copper ; Stainless Steel ; Max length 200m. specials 300m. + Sample vent x 2 – 10mm. Tubing entry – enclosure base / side option
|
|